Technical Specifications

emiCLAD Technical Summary

Physical Properties
PropertyStandardFire Rated TypeUnit
Panel Thickness4 - 4mm
Aluminum Skin Thickness0.3 - 0.5mm
Area Weight5.5 - 6.5 / 7.5 - 8.5kg / m2
Physical Properties
Core Physical & Mechanical Properties
PropertyStandardFire Rated TypeUnit
Shear Strength (Mpa)ASTM C393/C393M-1632.8 - 33Mpa (N/mm2)
180° Peel StrengthISO 8510-2:200617.1 - 16.7N/mm
Drum Peel StrengthASTM D1781-98128 - 126.8N.mm / mm
Bending StrengthASTM C393/C393-16151 - 152.8Mpa (N/mm2)
Bend Modulus (Mpa)ASTM C393/C393-162.36X104 / 2.4X104Mpa (N/mm2)
Physical Properties
Core Thermal Properties
PropertyStandardFire Rated TypeUnit
Heat Deflection Temperature °CISO 75-2:2013100 - 100°C
Linear Thermal ExpansionASTM D696-16116 - 116.3μm/m°c
Thermal Resistance "R Value"ASTM C518-171.38 - 1.38m2.k/w
Thermal Conductivity "μ Value"ASTM C518-171.85 - 1.85w/m2.k
Physical Properties
Fire Resistance Properties
PropertyStandardResult AResult B
Flame Spread Index (FSI) Smoke developed Index (SDI)ASTM-E845-5Class A
Self Ignition Temp (FIT), °CASTM D1929-16361.3C m2.k / w
FTIR Baseline TestingASTM E 1252-98Baseline-
Classification of reaction to fire Performance includes BS EN ISO 11925_2:2010 BS EN 13823:2010 +A1:2014EN 13501-1B-S1,d0FR-B
Physical Properties
Dimension Tolerances
PropertiesProperties DimensionTolerance
Panel Dimension (mm)Width (mm)±2
Panel Dimension (mm)Length (mm)±3
Panel Dimension (mm)Thickness (mm)± 0.2
Aluminum Skin Thickness± 0.2
Coating
Panel Coating requirements (coating method: Panels coating characteristics)
PropertyStandardRequirementsResult
Coating ThicknessISO 2808 - 2019≥ 30mm ≥ 23mm45 external wall 38 internal wall
Gloss DeviationISO 2813:2014≤ 10mm7.1
Specular GlossASTM D523@60°15 - 3532.2 units
Pencil HardnessGSO ISO 15184≥ HB4H
Coating Adhesion (18°C - 27°C)ISO 2409:2013No RemovalExcellent / Grade 1 No Removal
Brush Resistance StainISO 11988No change at 10,000 cycle ≤ 5%1.09% Pass
Boiling Water Test (99°C - 100°C @ 20mins)ISO 2812 - 2 2014No changeExcellent
Impact ResistanceISO 6272 - 11 kg weight dropped from 100cm heightNo peel off, no cracks
Coating Flexibility: T - bendISO 17132: 2010≤ 2 without any cracks or damagesNo cracks in coating
Abrasion ResistanceASTM D968 - 17≥ 2L / μm9 L /μm
Coating
Chemical Test
PropertyStandardRequirementsResult
Acid Resistance (15mins Spot Test)ISO 2812-1 2017No blister and visual changePass No change
AlkaliISO 2812-1 2017No adhesion loss or visual changePass No change
Oil ResistanceISO 2812-1 2017No changePass No change
Solvent Resistance (72 hours Test)ISO 2812-1 2017No adhesion loss or visual changePass No Visual change
Coating
Corrosion resistance
PropertyStandardRequirementsResult
Salt Spray 240 hours 50g / 1ISO 11997Blistering, Flaking, Chalking, Delamination CorrosionPass No change
Coating
Weathering
PropertyStandardRequirementsResult
2000 hours Xenon Arc LampISO 16474Blistering, Flaking, Chalking, Cracking, Delamination Rusting Gloss Change, Colour Change.No Change

ALUCLAD Technical Summary

Physical Properties
PropertyStandardFire Rated TypeUnit
Panel Thickness4 - 4mm
Aluminum Skin Thickness0.3 - 0.5mm
Area Weight5.5 - 6.5 / 7.5 - 8.5kg / m2
Physical Properties
Core Physical & Mechanical Properties
PropertyStandardFire Rated TypeUnit
Shear Strenght (Mpa)ASTM C393/C393M-1632.8 - 33Mpa (N/mm2)
180° Peel StrenghtISO 8510-2:200617.1 - 16.7N/mm
Drum Peel StrenghtASTM D1781-98128 - 126.8N.mm / mm
Bending StrenghtASTM C393/C393-16151 - 152.8Mpa (N/mm2)
Bend Modulus (Mpa)ASTM C393/C393-162.36X104 - 2.4X104Mpa (N/mm2)
Physical Properties
Core Thermal Properties
PropertyStandardFire Rated TypeUnit
Heat Deflection Temperature °CISO 75-2:2013100 - 100°C
Linear Thermal ExpansionASTM D696-16116 - 116.3μm/m°c
Thermal Resistance "R Value"ASTM C518-171.38 - 1.38m2.k/w
Thermal Conductivity "μ Value"ASTM C518-171.85 - 1.85w/m2.k
Fire Resistance Properties
PropertyStandardResult
Flame Spread Index (FSI) Smoke developed index (SDI)ASTM-E845 - 5 / Class A
Self Ignition Temp (FIT), °CASTM D1929-16361.3 (For B-s1,do) 509 (A2-s1,do) - C m2.k / w
FTIR Baseline testingASTM E 1252-98Baseline / -
Classification of reaction to fire Performance includes BS EN ISO 11925_2:2010 BS EN 13823:2010 +A1:2014EN 13501-1B-S1,d0 / FR-B
Classification of reaction to fire Performance includes ISO 1716 EN 13823 +A1:2014EN 13501-1A2-s1,do / FR-A
Dimension Tolerances
PropertiesDimensionTolerance
Panel Dimension (mm)Width (mm)±2
Panel Dimension (mm)Length (mm)±3
Panel Dimension (mm)Thickness (mm)± 0.2
Aluminum Skin Thickness± 0.2
Coating
Panel Coating requirements (coating method: Panels coating characteristics)
PropertyStandardRequirementsResult
Coating ThicknessISO 2808 - 2019≥ 30mm ≥ 23mm45 external wall 38 internal wall
Gloss DeviationISO 2813:2014≤ 10mm7.1
Specular GlossASTM D523@60°15 - 3532.2 units
Pencil HardnessGSO ISO 15184≥ HB4H
Coating adhesion (18°C - 27°C)ISO 2409:2013No RemovalExcellent / Grade 1 No Removal
Brush Resistance StainISO 11988No change at 10,000 cycle ≤ 5%1.09% Pass
Boiling Water Test (99°C - 100°C @ 20mins)ISO 2812 - 2 2014No changeExcellent
Impact ResistanceISO 6272 - 11 kg weight dropped from 100cm heightNo peel off, no cracks
Coating Flexibility: T - bendISO 17132: 2010≤ 2 without any cracks or damagesNo cracks in coating
Abrasion ResistanceASTM D968 - 17≥ 2L / μm9 L /μm
Coating
Chemical Test
PropertyStandardRequirementsResult
Acid Resistance (15mins Spot Test)ISO 2812-1 2017No blister and visual changePass No change
AlkaliISO 2812-1 2017No adhesion loss or visual changePass No change
Oil ResistanceISO 2812-1 2017No changePass No change
Solvent Resistance (72 hours Test)ISO 2812-1 2017No adhesion loss or visual changePass No Visual change
Coating
Corrosion resistance
PropertyStandardRequirementsResult
Salt Spray 240 hours 50g / 1ISO 11997Blistering, Flaking, Chalking, Delamination CorrosionPass No change
Coating
Weathering
PropertyStandardRequirementsResult
2000 hours Xenon Arc LampISO 16474Blistering, Flaking, Chalking, Cracking, Delamination Rusting Gloss Change, Colour Change.No Change
en_USEnglish